Case Study: Roof Restoration with Mechanically Fixed TPO Membrane in Mangawhai Heads
A homeowner in Mangawhai Heads approached The Waterproofer with concerns about their deteriorating torch-on roof. The torchon roof had previously been addressed by way of a coating system. The coating system was blistered and cracked and too thin all over, it was disintegrating so contaminating the tank water collected off the roof and leaving the home vulnerable to leaks and water damage.
The failed coating system presented significant challenges: Recoating was not a viable option due to extensive blistering and cracking. Removal of the old membrane would be expensive and disruptive to the homeowner.
The Waterproofer proposed a cost-effective and durable solution: mechanically fixed single-ply TPO membrane installation.
2. Roof Cleaning: The roof area was cleaned to remove all debris, first disconnecting the downpipes so debris did not fall into the drinking water.
3. TPO Membrane Installation: A mechanically fixed single-ply TPO membrane was installed over the existing roof surface. The membrane was mechanically fixed into the plywood substrate to ensure stability and longevity.
4. Detailing and Waterproofing: All roof penetrations were meticulously detailed and sealed to prevent water ingress. A fire-rated decktite was installed around the chimney area for added protection.
5. Flashing Reinstatement: Flashings were removed and reinstated to get the membrane up and under.
Cost-Effective Solution: By avoiding the costly removal of the old membrane, the homeowner saved both time and money while achieving a high-quality roof restoration.
Improved Aesthetics: The new TPO membrane gave the roof a fresh and modern appearance, enhancing the overall aesthetic of the home.